Most of the appliance door and panel projects published on this site are specified as tempered, or toughened, glass. For OEM and ODM buyers, that is not only a material label. It is a process sequence: the outline, edges, holes and cutouts have to be finished first, then the panel is tempered, and only then does it belong in an appliance assembly. This guide explains what that means in practice at ZITA Glass, using process points and project examples already documented on our public pages.
ZITA Glass is the English-language site of Foshan Shunde Zhitai Glass Industrial Co., Ltd., a custom appliance-glass manufacturer in Shunde, Foshan, Guangdong, China. The factory covers about 30,000 square meters and has more than 300 employees. Published capabilities include glass cutting, edge and corner grinding, drilling, CNC machining, tempering, silk-screen and UV digital printing, coating, inspection and protective packaging. That path is how tempered appliance glass is made here, not a catalog of generic sheet glass.
On this site, “tempered appliance glass” means a custom panel that has been cut and processed to a drawing and then toughened in a tempering furnace before it is packed for an appliance manufacturer. The homepage lists six glass tempering lines among the factory’s process equipment. About and the homepage both describe tempering as part of the same production path as cutting, drilling, printing and coating.
That is a different brief from buying a standard tempered pane. An appliance panel usually has a defined outline, an edge finish, and often holes, cutouts, windows or printed graphics that have to register to the door, hob, hood or control assembly. ZITA Glass reviews those features against customer drawings to confirm that the part can be processed and tempered as drawn, not to set a standard thickness or heat rating for every appliance.
The same plant also produces related tempered components that are specified differently from an outer door, including refrigerator glass shelves and sliding glass lids for commercial chest freezers. Name the part and the appliance at the start of the briefing so the review starts from the right family.
The live catalog is built around tempered glass for refrigerator doors, oven doors, gas hob and cooktop surfaces, and range hoods, with water dispenser panels also listed on About and the homepage. Public case studies use fully tempered glass for those kinds of parts:
Those thicknesses, print designs and test notes belong to the projects that published them. They are examples of how a tempered door or lid was documented, not defaults for a new model. A different door may need another thickness, an anti-glare refrigerator door surface, or a different print process. For a structured briefing on refrigerator doors or oven doors, see How to Specify Custom Refrigerator Door Glass for OEM Projects and Custom Oven Door Glass: What OEM Manufacturers Should Confirm Before Sampling.
The most important process constraint on the public site is also the easiest to miss on a late drawing change. The homepage FAQ states that holes and cutouts must be processed before glass tempering. A concise process landing is also available at Tempered Appliance Glass Process. Once a panel is tempered, those features cannot be added as a shop-floor afterthought. If the assembly needs mounting holes, a display window, a handle cutout or a shaped opening, they belong on the drawing that is reviewed before sampling.
Related process points already described on About, the homepage and the product pages include:
Printing and coating are part of the same project as tempering, but they are not interchangeable. A solid black silk-screen field, a fine-line logo, a UV decorative pattern and an anti-glare door surface are different offers. Linking the briefing to the closest live product page, whether that is custom oven front glass, gas hob glass or range hood control-panel glass, helps the review start from the right process path.
The homepage FAQ asks buyers to provide a technical drawing or panel dimensions, glass thickness, required quantity and application, plus details of holes, cutouts, edge finishing, printing artwork and the delivery destination where these are available. Custom dimensions, holes, cutouts, edge finishing and printed designs are reviewed against the drawings. Production feasibility and tolerances are confirmed before sampling.
Minimum order quantity and lead time are not published as fixed figures. The FAQ states that they depend on the glass specification, processing requirements, printed design and order volume, and are confirmed against the project details and required delivery date. Sample specifications, costs and preparation time are likewise confirmed after the drawing, glass material and printing requirements have been reviewed.
Quality credentials described on About include ISO 9001 and CGAC certifications, with RoHS compliance for applicable products and REACH and RoHS test reports available for confirmation against a given project. If a project needs a named test method or a pass criterion, state it in the briefing rather than assuming a method from another model or another case study.
For the wider drawing-to-packaging path, see the OEM Project Support page and From Drawing Review to Export Packaging: How ZITA Glass Supports an OEM Appliance Glass Project. Share the drawing, application, thickness, artwork and quantity via the Contact page or the product inquiry form so the factory can review the tempered-glass sequence against a real part, not a generic description of toughened glass.